MEASURING TRANSDUCERS

MEASURING TRANSDUCERS - P11, P13 and P20 series

■ Destined for the continuous conversion into an analog standard signal:
- a.c. current and a.c. voltage (P20Z),
- d.c. current and d.c. voltage (P11H, P20),
- temperature and resistance (P11T, P20),
- power in 1-phase and 3-phase networks (P11P, P13P),
■ Galvanic separation,
■ Possibility of programming ranges and the sensor type by means of the PD14 programmer
and free LPConfig software (P20)
■ Supply: 85...253 V a.c./d.c. or 20...50 V a.c./d.c.,
■ Overall dimensions: 22.5 × 120 × 100 mm and 45 × 120 × 100 mm.

PROGRAMMABLE MEASURING TRANSDUCERS WITH RS-485 - P12 series

■ Destined for the continuous conversion into a digital and analog standard signal:
- a.c. current and a.c. voltage,
- d.c. current and d.c. voltage,
- temperature, resistance,
- power, energy, power factor, angle, network frequency,
- r.p.m., impulses, frequency, period, rotational speed, working hours,
■ Outputs: relay (2), analog and digital RS-485 - MODBUS protocol,
■ Recording of the measured signal in programmed time segments, event recording,
■ LCD display, 2 × 8 digits,
■ Galvanic separation,
■ Supply: 85...253 V a.c./d.c. or 20...50 V a.c./d.c.,
■ Programmable inputs, measuring outputs and alarms
- by means of the keyboard, through the PD14 (USB) programmer or the RS-485 interface,
■ Overall dimensions: 45 × 120 × 100 mm.

PROGRAMMABLE TRANSDUCER OF POWER NETWORK PARAMETERS – P43 type

■ Destined for the conversion of 3-phase, 3 or 4-wire power network parameters,
in balanced or unbalanced systems,
■ 2 analog outputs,
■ 2 relay outputs (signaling measured quantity overflows),
■ Pulse output (control of 3-phase active energy consumption),
■ RS-485 and USB interfaces with Modbus protocol,
■ Built-in memory for the 15 minutes’ power profile,
■ Storage of maximal and minimal values,
■ Galvanic isolation,
■ Programmable current and voltage transformer ratios,
■ Transducer programming realized by means of a free delivered LPConfig software,
■ Overall dimensions: 90 x 120 x 100 mm.

P17 TRANSDUCER AND P17G SEPARATOR – SUPPLIED FROM A CURRENT LOOP

■ Destined for the signal conversion from temperature sensors (Pt100, J, K) or standard
voltage signals (0…60 mV, 0…10 V) into the current signal 4…20 mA (P17),
■ Destined for the electric isolation of the current signal without an additional supply voltage (P17G),
■ Input: 0/4…20 mA (P17G),
■ Output: 0/4...20 mA (P17G),
■ Overall dimensions: 6.2 x 100 x 77.5 mm.

 